Showing 31–37 of 37 results

  • Binder – Standard-Incubators – Series BD Classic.Line – With natural convection

    The BINDER incubator of the BD series with natural convection is the specialist in long-term and stable continuous operation. This incubator is specially designed for gentle incubation of organisms, as well as conditioning of heat-sensitive media or microbiological heating.

    Benefits

    • Safe and reproducible incubation even under high batch throughputs in long-term operation
    • Disinfection routine at 100 °C
    • Stable atmosphere by inner glass door

    Incubator with Natural Convection from BINDER

    If you are looking for stable incubation processes guaranteed, you need look no further than incubators from BINDER. Series BD incubators function with natural convection and, thanks to their state-of-the-art technical equipment, are a reliable choice for the incubation of microbiological cultures.

    This BINDER incubator with natural convection comes in a range of versions and sizes. Operating within a temperature range of between 5 °C and 100 °C, they are equipped with the proven APT.line™ preheating chamber technology and an adjustable exhaust air flap. The inner door is made from tempered safety glass, guaranteeing a stable atmosphere.

     

    Incubator with Natural Convection for Optimum, Reproducible Results

    This BINDER incubator with natural convection is really easy to use thanks to the controller with timer functions and the visual temperature alarm. The units can be stacked on top of one another for an optimum ratio between stand space and usable space.

    Plus, compared to similar incubators, the units from BINDER boast high levels of temperature accuracy, excellent usability, and options for ease of cleaning. The incubator with natural convection guarantees results that are reproducible at any time, with uniform incubation conditions even under high batch throughputs in long-term operation. These incubators are ideal for all incubation processes within the fields of research, production, and quality assurance.

  • Binder – Standard-Incubators – Series BD-S Solid.Line – With natural convection

    The new products in the Solid.Line impress with their tried-and-tested BINDER quality and reliability. They are suited to incubation. The attributes of the Solid.Line are geared towards the application in question and therefore used in research and quality assurance.

    Benefits

    • Easy handling
    • Accurate temperature control
    • Simple and ergonomic door opening
  • Binder – Standard-Incubators – Series BF Avantgarde.Line – With forced convection

    The BINDER incubator of the BF Avantgarde. Line series with forced convection is suitable for all gentle incubation applications, particularly under a full load and large batch throughputs. This incubator is extremely homogeneous and has quick recovery times.

    Key Features

    • Excellent temporal and spatial temperature accuracy
    • High process reliability
    • 100 °C disinfection routine
     
  • Binder – Standard-Incubators – Series BF Classic.Line – With forced convection

    The BINDER incubator of the BF series with mechanical convection is suitable for all gentle incubation applications, particularly under a full load and large batch throughputs. This incubator is extremely homogeneous and has quick recovery times.

    Incubators with Forced Convection for Challenging Incubation Tasks

    BINDER offers incubators to suit different laboratory requirements. Alongside incubators with mechanical adjustment, the Classic.Line also includes incubators with natural convection and, in the BF series, incubators with forced convection, which guarantee quick temperature equalization through forced convection after the chamber door has been opened.

    Operating within a temperature range of between 5 °C and 100 °C, these incubators with forced convection all have an adjustable exhaust air flap and the fan speed can be adjusted on an individual basis. The proven APT.line™ preheating chamber technology and the cooling system guarantee maximum precision and results that are reproducible in every laboratory test.

     

  • Binder – Ultra Low Temperature Freezers – Series UF V – With climate-neutral refrigerants

    The BINDER ultra low temperature freezer ensures the safe storage of samples at -90 °C. It combines outstanding environmental friendliness with low energy consumption, convenient operation and an individual safety concept.

     

    Ultralow Temperature Freezers with VIP Insulation from BINDER

    BINDER ultralow temperature freezers with VIP insulation and electromechanical door lock offer maximum levels of safety for the storage of products and samples thanks to their multi-level safety concept and electronic protection against unauthorized access. Guaranteeing a constant low temperature, the ultralow temperature freezers are ideal for the stable, long-term storage of samples from the chemical, medical, and biological fields.

    The temperature range inside the ultralow temperature freezers is -40 °C to -86 °C, with the option to adjust this to the accuracy of one degree and regulate it using a controller. The controller’s keypad can be locked as required and the adjustment menus can be password-protected. The fault analysis system built into the controller kicks in if changes in temperature are detected, emitting visual and acoustic warnings and alarms.

  • Binder – Vacuum Drying Chambers – Series VD – For non-flammable solvents

    Both BINDER vacuum drying chamber models enable effective drying without residue or damaging the material being dried. With their proven technological features, the excellently address the strict requirements of industrial and scientific laboratories.

    Samples and similar materials incorporating flammable and non-flammable solvents can be dried, depending on the individual use. The chambers use a unique safety design that, together with accustomed outstanding performance, sets the bar in terms of quality and safety.

    BINDER Vacuum Drying Chambers for High Performance and Safety

    BINDER vacuum drying chambers live up to the highest of standards when it comes to safety, quality, and performance. Samples can be dried quickly, effectively, and gently, with homogeneous temperature distribution across the usable space and a drying process free from condensation. On top of all this, high levels of safety are guaranteed with the vacuum drying chambers. Adjustment without overshooting provides maximum protection for samples, while a unique, sophisticated safety concept is in place where operation is concerned. In two series, BINDER has models available for both non-flammable and flammable solvents. The VDL series for flammable solvents also has an explosion-proof interior for added safety.

  • Binder – Vacuum drying chambers – Series VDL – For flammable solvents

    BINDER VDL series safety vacuum drying chambers ensure maximum safety when drying organic solvents.

    Benefits

    • Fast, gentle drying
    • Optimum heat transfer through large thermal conducting plates
    • Safe working thanks to ATEX-compliant safety concept
    • Also option of modular complete system with vacuum pump and pump chamber

    Vacuum Drying Chambers for Flammable Solvents

    In its VDL series, BINDER has developed special vacuum drying chambers for flammable solvents. These innovative drying chambers combine effective drying with a sophisticated safety concept. Drying is taken care of quickly and without residues, scaling, or oxidation.

    Safety is guaranteed by the vacuum drying chambers for flammable solvents first and foremost by their explosion-proof interior. Adjustment without overshooting also provides maximum protection for samples, while a unique safety concept is in place where operation is concerned. The design and innovative equipment comply with ATEX II 2/3/- G standards.

     

    BINDER Vacuum Drying Chambers for Quick Drying and Quality That Lasts

    As well as boasting high levels of safety, the drying chambers impress with their quick drying process. Heat is transferred to the sample directly using heat conductor plates, and the patented APT.line™ preheating chamber technology makes sure that sample drying is homogeneous across the entire usable space. Quick, gentle, and free from condensation, drying takes place on aluminum expansion racks that can be flexibly adjusted.

    BINDER vacuum drying chambers for flammable solvents cover a temperature range of between 8 °C and 110 °C. Alongside a quick drying process and high levels of process reliability, the chambers are also quick and easy to clean thanks to the smooth inner chamber with rounded corners, the stainless steel interior coating, and the removable racks.

    With vacuum drying chambers for flammable solvents from BINDER, performance, quality, and safety go hand in hand, meaning operation is safe and simple for you and optimum results are guaranteed.