Binder – Standard-Incubators – Series BD Classic.Line – With natural convection
The BINDER incubator of...
The BINDER incubator of the BD series with natural convection is the specialist in long-term and stable continuous operation. This incubator is specially designed for gentle incubation of organisms, as well as conditioning of heat-sensitive media or microbiological heating.
Benefits
- Safe and reproducible incubation even under high batch throughputs in long-term operation
- Disinfection routine at 100 °C
- Stable atmosphere by inner glass door
Incubator with Natural Convection from BINDER
If you are looking for stable incubation processes guaranteed, you need look no further than incubators from BINDER. Series BD incubators function with natural convection and, thanks to their state-of-the-art technical equipment, are a reliable choice for the incubation of microbiological cultures.
This BINDER incubator with natural convection comes in a range of versions and sizes. Operating within a temperature range of between 5 °C and 100 °C, they are equipped with the proven APT.line™ preheating chamber technology and an adjustable exhaust air flap. The inner door is made from tempered safety glass, guaranteeing a stable atmosphere.
Incubator with Natural Convection for Optimum, Reproducible Results
This BINDER incubator with natural convection is really easy to use thanks to the controller with timer functions and the visual temperature alarm. The units can be stacked on top of one another for an optimum ratio between stand space and usable space.
Plus, compared to similar incubators, the units from BINDER boast high levels of temperature accuracy, excellent usability, and options for ease of cleaning. The incubator with natural convection guarantees results that are reproducible at any time, with uniform incubation conditions even under high batch throughputs in long-term operation. These incubators are ideal for all incubation processes within the fields of research, production, and quality assurance.
Binder – Standard-Incubators – Series BD-S Solid.Line – With natural convection
The new products in the Solid.Line impress with their tried-and-tested BINDER quality and reliability. They are suited to incubation. The attributes of the Solid.Line are geared towards the application in question and therefore ...
The new products in the Solid.Line impress with their tried-and-tested BINDER quality and reliability. They are suited to incubation. The attributes of the Solid.Line are geared towards the application in question and therefore used in research and quality assurance.
Benefits
- Easy handling
- Accurate temperature control
- Simple and ergonomic door opening
Binder – Standard-Incubators – Series BF Avantgarde.Line – With forced convection
The BINDER incubator of...
The BINDER incubator of the BF Avantgarde. Line series with forced convection is suitable for all gentle incubation applications, particularly under a full load and large batch throughputs. This incubator is extremely homogeneous and has quick recovery times.
Key Features
- Excellent temporal and spatial temperature accuracy
- High process reliability
- 100 °C disinfection routine
Binder – Standard-Incubators – Series BF Classic.Line – With forced convection
The BINDER incubator of...
The BINDER incubator of the BF series with mechanical convection is suitable for all gentle incubation applications, particularly under a full load and large batch throughputs. This incubator is extremely homogeneous and has quick recovery times.
Incubators with Forced Convection for Challenging Incubation Tasks
BINDER offers incubators to suit different laboratory requirements. Alongside incubators with mechanical adjustment, the Classic.Line also includes incubators with natural convection and, in the BF series, incubators with forced convection, which guarantee quick temperature equalization through forced convection after the chamber door has been opened.
Operating within a temperature range of between 5 °C and 100 °C, these incubators with forced convection all have an adjustable exhaust air flap and the fan speed can be adjusted on an individual basis. The proven APT.line™ preheating chamber technology and the cooling system guarantee maximum precision and results that are reproducible in every laboratory test.
Binder – Ultra Low Temperature Freezers – Series UF V – With climate-neutral refrigerants
The BINDER ultra low temperature freezer ensures the safe storage of samples at -90 °C. It combines outstanding environmental friendliness with low energy consumption, convenient operation and an individual saf...
The BINDER ultra low temperature freezer ensures the safe storage of samples at -90 °C. It combines outstanding environmental friendliness with low energy consumption, convenient operation and an individual safety concept.
Ultralow Temperature Freezers with VIP Insulation from BINDER
BINDER ultralow temperature freezers with VIP insulation and electromechanical door lock offer maximum levels of safety for the storage of products and samples thanks to their multi-level safety concept and electronic protection against unauthorized access. Guaranteeing a constant low temperature, the ultralow temperature freezers are ideal for the stable, long-term storage of samples from the chemical, medical, and biological fields.
The temperature range inside the ultralow temperature freezers is -40 °C to -86 °C, with the option to adjust this to the accuracy of one degree and regulate it using a controller. The controller’s keypad can be locked as required and the adjustment menus can be password-protected. The fault analysis system built into the controller kicks in if changes in temperature are detected, emitting visual and acoustic warnings and alarms.
Binder – Vacuum Drying Chambers – Series VD – For non-flammable solvents
Both BINDER vac...
Both BINDER vacuum drying chamber models enable effective drying without residue or damaging the material being dried. With their proven technological features, the excellently address the strict requirements of industrial and scientific laboratories.
Samples and similar materials incorporating flammable and non-flammable solvents can be dried, depending on the individual use. The chambers use a unique safety design that, together with accustomed outstanding performance, sets the bar in terms of quality and safety.
BINDER Vacuum Drying Chambers for High Performance and Safety
BINDER vacuum drying chambers live up to the highest of standards when it comes to safety, quality, and performance. Samples can be dried quickly, effectively, and gently, with homogeneous temperature distribution across the usable space and a drying process free from condensation. On top of all this, high levels of safety are guaranteed with the vacuum drying chambers. Adjustment without overshooting provides maximum protection for samples, while a unique, sophisticated safety concept is in place where operation is concerned. In two series, BINDER has models available for both non-flammable and flammable solvents. The VDL series for flammable solvents also has an explosion-proof interior for added safety.
Binder – Vacuum drying chambers – Series VDL – For flammable solvents
BINDER VDL series safet...
BINDER VDL series safety vacuum drying chambers ensure maximum safety when drying organic solvents.
Benefits
- Fast, gentle drying
- Optimum heat transfer through large thermal conducting plates
- Safe working thanks to ATEX-compliant safety concept
- Also option of modular complete system with vacuum pump and pump chamber
Vacuum Drying Chambers for Flammable Solvents
In its VDL series, BINDER has developed special vacuum drying chambers for flammable solvents. These innovative drying chambers combine effective drying with a sophisticated safety concept. Drying is taken care of quickly and without residues, scaling, or oxidation.
Safety is guaranteed by the vacuum drying chambers for flammable solvents first and foremost by their explosion-proof interior. Adjustment without overshooting also provides maximum protection for samples, while a unique safety concept is in place where operation is concerned. The design and innovative equipment comply with ATEX II 2/3/- G standards.
BINDER Vacuum Drying Chambers for Quick Drying and Quality That Lasts
As well as boasting high levels of safety, the drying chambers impress with their quick drying process. Heat is transferred to the sample directly using heat conductor plates, and the patented APT.line™ preheating chamber technology makes sure that sample drying is homogeneous across the entire usable space. Quick, gentle, and free from condensation, drying takes place on aluminum expansion racks that can be flexibly adjusted.
BINDER vacuum drying chambers for flammable solvents cover a temperature range of between 8 °C and 110 °C. Alongside a quick drying process and high levels of process reliability, the chambers are also quick and easy to clean thanks to the smooth inner chamber with rounded corners, the stainless steel interior coating, and the removable racks.
With vacuum drying chambers for flammable solvents from BINDER, performance, quality, and safety go hand in hand, meaning operation is safe and simple for you and optimum results are guaranteed.
Biolin – Attension Theta Optical Tensiometers
Attension® offers leading contact angle and surface tension solutions for industrial quality control and R&D as well as for academic research. The core of Attension solutions is a combination of easy-to-use, smart instrumen...
Attension® offers leading contact angle and surface tension solutions for industrial quality control and R&D as well as for academic research. The core of Attension solutions is a combination of easy-to-use, smart instrumentation with broad surface science capabilities.
Measurements
- Static contact angle
- Dynamic contact angle
- Roll-off angle
- Surface free energy (SFE)
- Surface tension
- Interfacial tension
- Batch contact angle
- Roughness corrected contact angle
- Interfacial rheology (viscoelasticity)
Technology
An optical tensiometer records drop images and analyzes the drop shape automatically. The drop shape is a function of the surface tension of the liquid, gravity and the density. On a solid, the drop shape and the contact angle also depends on the properties of the solid (e.g. surface free energy, topography). The captured image is analyzed with a drop profile fitting method in order to determine contact angle and surface tension. Surface free energy can be calculated by performing contact angle measurements with several known liquids.
As an optical method, the measurement precision of optical tensiometers depends on the quality of the pictures and the analysis software. Attension Optical Tensiometers utilize a high quality monochromatic cold LED light source to minimize undesirable sample evaporation. Image quality is guaranteed by a high-resolution digital camera, quality optics and the accuracy of the drop fitting method.
Biolin – Force Tensiometers
Measurements
- Surface tension
- Interfacial tension
- Critical Micelle Concentration
- Dynamic contact angle
- Surface free energy
- Powder w...
Measurements
- Surface tension
- Interfacial tension
- Critical Micelle Concentration
- Dynamic contact angle
- Surface free energy
- Powder wettability
- Density
- Sedimentation
- Adhesion force
Full Automation for High Precision
The systems can be fully automated, avoiding user variation and saving you time. Highly precise measurements can be performed easily with just one click.
Optimized Yet Versatile
Sigma 700 and 701 have full support of all measurement modes, making them adaptable to all measurements and applications. However, they are also optimized for different experiments. Sigma 700 is the optimal choice especially for powder wettability and contact angle experiments. Sigma 701 is a great choice for surface tension and interfacial tension experiments due to its very high sensitivity.
Sophisticated Software
The OneAttension Software provide all measurement modes, full automation, easy measurement setup and live results. But above all, it is really user friendly and intuitive.
Biolin – QCM-D Instruments
QSense® is the world-leading, premium QCM-D solution for nanoscale tracking of interactions at surfaces and interfaces. It can provide you with unique, reproducible, in-depth data with high productivity and ease of use along the way.
This...
QSense® is the world-leading, premium QCM-D solution for nanoscale tracking of interactions at surfaces and interfaces. It can provide you with unique, reproducible, in-depth data with high productivity and ease of use along the way.
This enables a fundamental understanding of processes, an early indication of real-life outcome and the ability to optimize products and processes for authentic conditions. By investing in a QSense instrument you put yourself and your team at the forefront of scientific progress and technological innovation.
Claind – Hydrogen Generator – HyGen
- Designed for Carrier Gas in GC, GC-MSD and “FAST GC”
- UHP Purity that meets the needs required by the track analysis
- Security system with audible alarms, display messages and automatic production stop in case of gas leak...
- Designed for Carrier Gas in GC, GC-MSD and “FAST GC”
- UHP Purity that meets the needs required by the track analysis
- Security system with audible alarms, display messages and automatic production stop in case of gas leaks
- Available the automatic Switch with inert gas when Hydrogen alarm
- Parallel connection from series up to 4 stacked generators
Claind – Nitrogen Generator – NiGen
Our range of nitrogen generators consists of 11 different types of devices with varying purity levels up to 99.9995%. These generators are designed to meet industrial and analytical needs, where the production of ultra-pure nitrogen is often requ...
Our range of nitrogen generators consists of 11 different types of devices with varying purity levels up to 99.9995%. These generators are designed to meet industrial and analytical needs, where the production of ultra-pure nitrogen is often required. Backed by our proprietary Fast Purity® patent, all our nitrogen generators achieve the desired maximum purity in reduced time, progressively increasing gas self generation efficiency.
Claind – Nitrogen Generator – NiGen LCMS
- Designed to satisfy the needs of all LCMS analyzers on the market
- The PSA technology with molecular sieves, used in the NiGen series, are drastically reducing the O2 and H2O residual but also the HC presence in the air, offering an ...
- Designed to satisfy the needs of all LCMS analyzers on the market
- The PSA technology with molecular sieves, used in the NiGen series, are drastically reducing the O2 and H2O residual but also the HC presence in the air, offering an extremelly pure nitrogen output (phthalate-free)
- Built-in compressor oil free including 2 x 50 l. tanks for Compressed Air and Nitrogen
- Highly reliabile Air compressor with maintenance required only after 16,000 hours of work
- 2 gas outlets available: UHP Nitrogen and Oil Free Air
Claind – UHP Air Generator – AirGen GC
The AirGen GC delivers ultra-high purity zero air to ensure optimal gas chromatography performance, making it suitable for various GC detectors.
The AirGen GC delivers ultra-high purity zero air to ensure optimal gas chromatography performance, making it suitable for various GC detectors.
DataPhysics – DCAT – Dynamic contact angle measuring devices and tensiometer
The dynamic contact angle measuring devices and tensiometer of the DCAT series are universal measuring devices for the force-based measurement of interfacial parameters and phenomena.
Surface tension ac...
The dynamic contact angle measuring devices and tensiometer of the DCAT series are universal measuring devices for the force-based measurement of interfacial parameters and phenomena.
Surface tension acts to contract and minimise any liquid surface. If a surface is being enlarged by the formation of a liquid lamella, as a test body, such as a Wilhelmy plate or Du Noüy ring, is in contact with it, the surface tension exerts a tensile force that can be measured. Within a tensiometer this force is measured by a high precision weighing system and, hence, the surface tension of the liquid can be calculated.
Using a tensiometer, also the interfacial tension between two liquids can be measured with the help of a test body. Since tensiometry is based on force measurements it is – in contrast to the optical analysis of pendant drops – not necessary that one of the liquids is transparent or that the refractive index differs between the two liquids. Therefore, tensiometry is in many cases a handy alternative to the optical measurement of surface and interfacial tensions.
test block for Laos
Your download – just a few steps away
Please enter your details here:
test